Description
Old Part Numbers: CW207594AV
View AllClose
135 PSI cut-on, 175 PSI cut-off w/ 90 degree quick-lock unloader valve. 4-port manifold. NO on/off switch
Extra Details
If the 90-degree unloader valve leaks (where the 1/4" bleeder line installs) constantly after the compressor shuts off, you have a defective tank Check Valve; your pressure switch is okay.